Automation & Vision Systems
Measuring range | ±10 mm |
Operating voltage, nominal value | PoE (typically 48 V) |
Power consumption | max. 2 W |
Electrical connection | M 8 socket D-coded 4-pole (Ethernet PoE) |
Ambient temperature | +10 °C to +50 °C |
Storage temperature | -25 °C to +80 °C |
Relative humidity | 15 % to 95 % (non-condensing) |
Resolution | 0,02 mm |
Linearity | ±0,1 mm |
Thread and strip width | min. 0,2 mm |
Wavelength | 850 nm |
Scanning rate | 1 kHz |
Temperature drift (typical) at a relative atmospheric humidity of 60 % | Approx. 0.025 mm/K |
Cable length | max. 100 m |
Protection class with suitable connector inserted | max. IP 54 |
Weight | Approx. 0,3 kg |
Dimensions (L x W x H) | 105 x 50 x 40 mm |
Operating pressure | Min. 0.1 bar |
Max. 0.2 bar | |
Service unit filter | 5 μm |
Service unit residual oil content | <0.01 mg/m3 |
Clearing device (optional) | |
Operating pressure | min. 0,1 bar max. 0,2 bar |
Service unit filter | 5 μm |
Service unit residual oil content | <0,01 mg/m³ |